ALIPLAST Imperial

Imperial System
A wide range of possibilities

Imperial i+

  • The system is designed for windows, doors and shop windows with high thermal insulation parameters
  • High thermal insulation power was achieved by applying special thermal inserts slid between thermal separators and around the glass pane
  • Large number of shapes in the system guarantees obtaining desired appearance and structural strength
  • Option of installing windows in facade systems
  • Glazing strips available in rectangular and circular variant
  • Shapes of profiles suitable for installation of various peripheral hardware, including hidden hinges and pvc hardware
  • A wide range of glazing allows using all types of single and double cavity, acoustic and anti-burglary glass panes
  • Profile drainage in two variants: traditional and hidden
  • Option of bending profiles (detailed specification of profiles and detailed technical parameters of profile bending process are available in the customer area of the website www.aliplast.pl)
  • The system is desiged for use in residential and public buildings, and also allows designing modern window solutions in multiple variants
  • Design of systems IP i, IP i+ is based on proven, extensive and recognized base system Imperial
  • There is possibility of use Flyscreen and Insect System
  • A wide range of colours – RAL palette (Qualicoat 1518), texture colours, Aliplast Wood Colour Effect (wood-like colours), Aliplast Loft View – colours imitating stone surfaces (Qualideco PL-0001), anodised colour (Qualanod 1808), bi-colour.

Imperial SU

  • Three-chamber window system with thermal insulation designed for designing windows with hidden sash, invisible from the outside
  • The system features specially designed shape of the frame hiding the full height of sash profile
  • A wide range of glazing allows using all types of single and double cavity, acoustic and anti-burglary glass panes
  • Profile drainage in two variants: traditional and hidden
  • The option of bending profiles (detailed specification of profiles and detailed technical parameters of profile bending process are available in the customer area of the website www.aliplast.pl)
  • Hidden sash system is the system preferred by designers, as it allows “hiding” windows in aluminium and glass structure; thanks to application of this solution opened and fixed window segments look identical from the outside
  • A wide range of colours – RAL palette (Qualicoat 1518), texture colours, Aliplast Wood Colour Effect (wood-like colours), Aliplast Loft View – colours imitating stone surfaces (Qualideco PL-0001), anodised colour (Qualanod 1808), bi-colour

Imperial OUT

  • Window system designated for designing tilt out and turn out windows
  • System Imperial OUT is fully compatible with window system Imperial (they share system elements: connectors, gaskets, glazing strips)
  • System Imperial OUT features faced internal surface of the frame and the sash
  • Turn out windows can be fitted with two types of hinges: rotating hinges or scissor hinge; window hardware used allows tilting the top or the bottom of the window outwards; option of turn out window with the limit stop
  • Available option of integrating windows with walls by using reversing profile
  • Option of bending profiles (detailed specification of profiles and detailed technical parameters of profile bending process are available in the customer area of the website www.aliplast.pl)
  • Maximum dimensions and weights of structures in Imperial OUT system:
  • – Tilt out windows:
  • Minimum width and height of sash 500 mm, maximum width and height of sash 2000 mm, maximum weight of sash 100 kg for tilt out windows
  • – Turn out windows:
  • Minimum width and height of sash 500 mm, maximum width of sash 1500 mm, height of sash 3000 mm, maximum weight of sash 120 kg for turn out windows
  • System IP OUT is available in the variant with improved thermal insulation power:
  • Available options: IP OUTi with additional, peripheral thermal insulation, at the profile-glass interface; IP-OUT i+ with additional thermal insulation between thermal spacers
  • This system is a very popular in Nordic countries and on British Isles; perfectly matching old and stylized manor houses, wood cabins or simple Scandinavian type houses; shutters are often used with such windows
  • A wide range of colours – RAL palette (Qualicoat 1518), texture colours, Aliplast Wood Colour Effect (wood-like colours), Aliplast Loft View – colours imitating stone surfaces (Qualideco PL-0001), anodised colour (Qualanod 1808), bi-colour

Imperial 800 i+

  • Door system designed for designing doors with high thermal insulation parameters
  • The system is compatible with Imperial system – thanks to adaptive profiles designs in series IP800 can be integrated with Imperial shop windows
  • The system features very good anti-burglary properties (the lock is situated far from the outer side)
  • Thermal insulation lintel is used, which can be dismantled following door installation in the frame
  • The system offers solutions preventing catching of fingers (antyfinger)
  • Option of bending profiles (detailed specification of profiles and detailed technical parameters of profile bending process are available in the customer area of the website www.aliplast.pl)
  • The system is also available in the variant with improved thermal insulation power (IP800i, Ip800i+), which was achieved by applying special thermal inserts slid between thermal separators and around the glass pane; such a solution improves the insulating power of the profile by 0,2 – 0,5 W/m2K
  • A wide range of colours – RAL palette (Qualicoat 1518), texture colours, Aliplast Wood Colour Effect (wood-like colours), Aliplast Loft View – colours imitating stone surfaces (Qualideco PL-0001), anodised colour (Qualanod 1808), bi-colour

Imperial system performance

DEPTH OF FRAME

IP: 75 mm
IP i+: 75 mm
IP SU: 65 mm
IP SU i: 65 mm
IP OUT: 65 mm
IP OUT i+: 65 mm
IP 800: 65 mm
IP 800_i+: 65 mm

DEPTH OF LEAF

IP: 74 mm
IP i+: 74 mm
IP SU: 68 mm
IP SU i: 68 mm
IP OUT: 74 mm
IP OUT i+: 74 mm
IP 800: 65 mm
IP 800_i+: 65 mm

GLAZING RANGE

IP: 14-51 mm
IP i+: 14-51 mm
IP SU: 4-41 mm
IP SU i: 4-41 mm
IP OUT: max 61 mm
IP OUT i+: max 61 mm
IP 800: 14-59 mm
IP 800_i+: 14-59 mm

THERMAL INSULATION UF

IP: Uf od 1,57 W/m2K
IP i+: Uf od 1,28 W/m2K
IP SU: Uf od 1,63 W/m2K
IP SU i: Uf od 1,27 W/m2K
IP OUT: Uf od 1,85 W/m2K
IP OUT i+: Uf od 1,68 W/m2K
IP 800: Uf od 1,84 W/m2K
IP 800_i+: Uf od 1,67 W/m2K

AIR PERMEABILITY

IP: Class 4; EN 12207
IP i+: Class 4; EN 12207
IP SU: Class 4; EN 12207
IP SU i: Class 4; EN 12207
IP OUT: Class 4; EN 12207
IP OUT i+: Class 4; EN 12207
IP 800: Class 4; EN 12207
IP 800_i+: Class 4; EN 12207

WINDLOAD RESISTANCE

IP: Class C4; EN 12210
IP i+: Class C4; EN 12210
IP SU: Class C5/B5; EN 12210
IP SU i: Class C5/B5 EN 12210
IP OUT: Class C5/B5; EN 12210
IP OUT i+: Class C5/B5; EN 12210
IP 800: 2400Pa; EN 12210
IP 800_i+: 2400Pa; EN 12210

WATERTIGHTNESS

IP: Class E1350; EN 12208
IP i+: Class E1350; EN 12208
IP SU: Class E1200; EN 12208
IP SU i: Class E1200; EN 12208
IP OUT: Class E900; EN 12208
IP OUT i+: Class E900; EN 12208
IP 800: Class 8A; EN 12208
IP 800_i+: Class 8A; EN 12208

DEPTH OF FRAME

IP: 75 mm
IP i+: 75 mm
IP SU: 65 mm
IP SU i: 65 mm
IP OUT: 65 mm
IP OUT i+: 65 mm
IP 800: 65 mm
IP 800_i+: 65 mm

GLAZING RANGE

IP: 14-51 mm
IP i+: 14-51 mm
IP SU: 4-41 mm
IP SU i: 4-41 mm
IP OUT: max 61 mm
IP OUT i+: max 61 mm
IP 800: 14-59 mm
IP 800_i+: 14-59 mm

AIR PERMEABILITY

IP: Class 4; EN 12207
IP i+: Class 4; EN 12207
IP SU: Class 4; EN 12207
IP SU i: Class 4; EN 12207
IP OUT: Class 4; EN 12207
IP OUT i+: Class 4; EN 12207
IP 800: Class 4; EN 12207
IP 800_i+: Class 4; EN 12207

DEPTH OF LEAF

IP: 75 mm
IP i+: 75 mm
IP SU: 65 mm
IP SU i: 65 mm
IP OUT: 65 mm
IP OUT i+: 65 mm
IP 800: 65 mm
IP 800_i+: 65 mm

THERMAL INSULATION UF

IP: Uf from 1,57 W/m2K
IP i+: Uf from 1,28 W/m2K
IP SU: Uf from 1,63 W/m2K
IP SU i: Uf from 1,27 W/m2K
IP OUT: Uf from 1,85 W/m2K
IP OUT i+: Uf from 1,68 W/m2K
IP 800: Uf from 1,84 W/m2K
IP 800_i+: Uf from 1,67 W/m2K

WINDLOAD RESISTANCE

IP: Class C4; EN 12210
IP i+: Class C4; EN 12210
IP SU: Class C5/B5; EN 12210
IP SU i: Class C5/B5 EN 12210
IP OUT: Class C5/B5; EN 12210
IP OUT i+: Class C5/B5; EN 12210
IP 800: 2400Pa; EN 12210
IP 800_i+: 2400Pa; EN 12210

WATERTIGHTNESS

IP: Class E1350; EN 12208
IP i+: Class E1350; EN 12208
IP SU: Class E1200; EN 12208
IP SU i: Class E1200; EN 12208
IP OUT: Class E900; EN 12208
IP OUT i+: Class E900; EN 12208
IP 800: Class 8A; EN 12208
IP 800_i+: Class 8A; EN 12208

SHORTCUTS

+ Our story

+ Why BN-STEP

+ Downloads

+ References

+ Contact

PRODUCTS

+ Windows

+ Doors

+ Entrance portals

+ Sliding elements

+ Glass facades

+ Blinds and shutters

+ Garage door

SYSTEMS

+ Aluminum systems

+ PVC systems

DO YOU HAVE A QUESTION?